{"id":6597,"date":"2015-04-01T15:59:07","date_gmt":"2015-04-01T19:59:07","guid":{"rendered":"https:\/\/cep-experts.ca\/?p=6597"},"modified":"2022-12-28T16:21:48","modified_gmt":"2022-12-28T21:21:48","slug":"la-problematique-des-systemes-disolation-des-facades-avec-enduit-acrylique","status":"publish","type":"post","link":"https:\/\/cep-experts.ca\/fr\/la-problematique-des-systemes-disolation-des-facades-avec-enduit-acrylique\/","title":{"rendered":"La probl\u00e9matique des syst\u00e8mes d&rsquo;isolation des fa\u00e7ades avec enduit acrylique"},"content":{"rendered":"\t\t<div class=\"et_pb_section et_pb_with_background et_section_regular breadcrumbs_section\">\r\n\t\t\t<div class=\" et_pb_row breadcrumbs_row\">\r\n\t\t\t\t<div class=\"et_pb_column et_pb_column_4_4 breadcrumbs_column\">\r\n\t\t\t\t\t<div class=\"et_pb_code et_pb_module breadcrumbs_module\">\r\n\t\t\t\t\t\t<span><span><a href=\"https:\/\/cep-experts.ca\/fr\/\">Accueil<\/a><\/span><\/span>\t\t\t\t\t<\/div> <!-- .et_pb_code -->\r\n\t\t\t\t<\/div> <!-- .et_pb_column -->\r\n\t\t\t<\/div> <!-- .et_pb_row -->\r\n\t\t<\/div>\r\n\t[et_pb_section fb_built=\u00a0\u00bb1&Prime; _builder_version=\u00a0\u00bb4.16&Prime; z_index_tablet=\u00a0\u00bb500&Prime; global_colors_info=\u00a0\u00bb{}\u00a0\u00bb][et_pb_row _builder_version=\u00a0\u00bb4.16&Prime; custom_padding=\u00a0\u00bb0px||0px|\u00a0\u00bb z_index_tablet=\u00a0\u00bb500&Prime; global_colors_info=\u00a0\u00bb{}\u00a0\u00bb][et_pb_column type=\u00a0\u00bb4_4&Prime; _builder_version=\u00a0\u00bb4.16&Prime; custom_padding=\u00a0\u00bb|||\u00a0\u00bb global_colors_info=\u00a0\u00bb{}\u00a0\u00bb custom_padding__hover=\u00a0\u00bb|||\u00a0\u00bb][et_pb_text _builder_version=\u00a0\u00bb4.19.4&Prime; hover_enabled=\u00a0\u00bb0&Prime; z_index_tablet=\u00a0\u00bb500&Prime; box_shadow_horizontal_tablet=\u00a0\u00bb0px\u00a0\u00bb box_shadow_vertical_tablet=\u00a0\u00bb0px\u00a0\u00bb box_shadow_blur_tablet=\u00a0\u00bb40px\u00a0\u00bb box_shadow_spread_tablet=\u00a0\u00bb0px\u00a0\u00bb global_colors_info=\u00a0\u00bb{}\u00a0\u00bb sticky_enabled=\u00a0\u00bb0&Prime;]<p>Avec une conscientisation environnementale accrue et l&rsquo;entr\u00e9e en vigueur des nouveaux r\u00e8glements concernant l&rsquo;efficacit\u00e9 \u00e9nerg\u00e9tique des b\u00e2timents, les propri\u00e9taires, gestionnaires, architectes et ing\u00e9nieurs sont \u00e0 la recherche de techniques innovatrices pour r\u00e9pondre \u00e0 ces nouveaux besoins. L&rsquo;augmentation de l&rsquo;isolation thermique de l&rsquo;enveloppe du b\u00e2timent est un moyen efficace de r\u00e9pondre \u00e0 certaines exigences en mati\u00e8re d&rsquo;efficacit\u00e9 \u00e9nerg\u00e9tique.<\/p>\n<p>Cet ajout d&rsquo;isolation peut \u00eatre effectu\u00e9 par l&rsquo;ext\u00e9rieur pour certains b\u00e2timents et faire partie int\u00e9grale du rev\u00eatement ext\u00e9rieur. Au cours des derni\u00e8res d\u00e9cennies, la raret\u00e9 de la main-d&rsquo;oeuvre de qualit\u00e9 pour la ma\u00e7onnerie et l&rsquo;augmentation des co\u00fbts des mat\u00e9riaux nobles ont contribu\u00e9 \u00e0 l&rsquo;\u00e9laboration des nouvelles technologies dans le domaine des rev\u00eatements ext\u00e9rieurs.<\/p>\n<p>Au cours des ann\u00e9es 1960, il y a eu l&rsquo;introduction des syst\u00e8mes d&rsquo;isolation \u00e0 rev\u00eatement en acrylique ou syst\u00e8me d&rsquo;isolation des fa\u00e7ades avec enduits (SIFE) sur le march\u00e9. L&rsquo;augmentation du facteur d&rsquo;isolation thermique, la flexibilit\u00e9 des d\u00e9tails architecturaux (corniches, corbeaux, arches, keystone, etc.) et la vari\u00e9t\u00e9 de finis et de couleurs ont contribu\u00e9 \u00e0 la popularit\u00e9 de ces syst\u00e8mes depuis leur introduction.<\/p>\n<p>Jusqu&rsquo;au d\u00e9but des ann\u00e9es 2000, le syst\u00e8me d&rsquo;isolation \u00e0 rev\u00eatement en acrylique \u00e9tait constitu\u00e9 d&rsquo;un isolant en polystyr\u00e8ne fix\u00e9 directement sur la membrane pare-air et le rev\u00eatement interm\u00e9diaire du b\u00e2timent (contreplaqu\u00e9, panneaux d&rsquo;agglom\u00e9r\u00e9 ou autres), sans espace d&rsquo;air ni cavit\u00e9 de drainage. Ce syst\u00e8me \u00e0 barri\u00e8re unique devait donc emp\u00eacher toutes infiltrations d&rsquo;eau derri\u00e8re le syst\u00e8me, car celui-ci ne pouvait pas les g\u00e9rer. En fait, l&rsquo;eau qui p\u00e9n\u00e9trait derri\u00e8re le parement d&rsquo;acrylique n&rsquo;avait pas d&rsquo;exutoire et ne pouvait se drainer ni s&rsquo;ass\u00e9cher, contrairement aux syst\u00e8mes \u00e0 principe pare-pluie, tels qu&rsquo;un mur de ma\u00e7onnerie comportant une cavit\u00e9 de drainage. Dans un mur \u00e0 principe pare-pluie, la cavit\u00e9 de drainage permet g\u00e9n\u00e9ralement \u00e0 l&rsquo;eau qui s&rsquo;y infiltrait, par absorption des mat\u00e9riaux, par les fissures ou autres, de s&rsquo;\u00e9couler vers l&rsquo;ext\u00e9rieur du syst\u00e8me et d&rsquo;\u00eatre ventil\u00e9 (par l&rsquo;interm\u00e9diaire des solins et des chantepleures).<\/p>\n<p>Le r\u00f4le du parement de ma\u00e7onnerie consiste donc \u00e0 limiter la p\u00e9n\u00e9tration de l&rsquo;eau de pluie sans l&#8217;emp\u00eacher compl\u00e8tement. Par contre, puisque l&rsquo;acrylique n&rsquo;absorbe pas l&rsquo;eau comme la ma\u00e7onnerie, il n&rsquo;\u00e9tait pas jug\u00e9 n\u00e9cessaire d&rsquo;avoir cette cavit\u00e9. Au fil des ann\u00e9es, de nombreux cas d&rsquo;infiltration d&rsquo;eau derri\u00e8re le parement ont d\u00e9menti cette croyance. En effet, lorsque la conception de l&rsquo;enveloppe ne pr\u00e9cise pas parfaitement les d\u00e9tails de construction ou, lorsque l&rsquo;ex\u00e9cution de ces d\u00e9tails n&rsquo;est pas impeccable, l&rsquo;eau de pluie peut se diriger derri\u00e8re le parement. L&rsquo;eau peut \u00e9galement se diriger derri\u00e8re le parement par des joints de scellant inad\u00e9quat au p\u00e9rim\u00e8tre des ouvertures, \u00e0 cause d&rsquo;un manque d&rsquo;entretien de ces joints, ou bien lorsque le parement d&rsquo;acrylique se fissure pour diverses raisons au fil du temps. Puisque cette infiltration d&rsquo;eau n&rsquo;est g\u00e9n\u00e9ralement pas visible, il est fr\u00e9quent qu&rsquo;elle perdure pendant des ann\u00e9es avant qu&rsquo;il y ait des indices d&rsquo;une probl\u00e9matique. Au moment de la d\u00e9couverte du probl\u00e8me, les rev\u00eatements interm\u00e9diaires et la structure sont g\u00e9n\u00e9ralement tr\u00e8s d\u00e9grad\u00e9s.<\/p>\n<p>Les photographies 1 et 2 d\u00e9montrent une structure de bois d\u00e9grad\u00e9e due \u00e0 des infiltrations d&rsquo;eau occasionn\u00e9es par des joints de calfeutrant d\u00e9ficients au p\u00e9rim\u00e8tre des fen\u00eatres. Les dommages \u00e0 la structure, visibles sur les photographies 3 et 4, r\u00e9sultent d&rsquo;un d\u00e9tail d&rsquo;ex\u00e9cution mal r\u00e9alis\u00e9 \u00e0 la jonction d&rsquo;un toit et d&rsquo;un mur. Dans les deux cas, les d\u00e9ficiences ont occasionn\u00e9 des infiltrations r\u00e9p\u00e9t\u00e9es qui se sont sold\u00e9es par une d\u00e9gradation avanc\u00e9e du substrat et de la structure, puisqu&rsquo;il n&rsquo;y avait pas de possibilit\u00e9 d&rsquo;\u00e9vacuer l&rsquo;eau.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-6599\" src=\"https:\/\/cep-experts.ca\/wp-content\/uploads\/2015\/04\/degradation-de-la-structure.png\" alt=\"\" width=\"1864\" height=\"698\" \/><\/p>\n<p>Selon la documentation technique des divers fabricants de syst\u00e8mes d&rsquo;isolation \u00e0 rev\u00ea\u00adtement acrylique datant des ann\u00e9es 2000 et avant, les panneaux d&rsquo;isolant \u00e9taient fix\u00e9s directement sur le substrat, tel que montr\u00e9 aux photographies \u00e9nonc\u00e9es pr\u00e9c\u00e9demment. Toutefois, dans les plus r\u00e9centes \u00e9ditions, nous observons un changement notable quant \u00e0 la m\u00e9thode d&rsquo;installation de ce syst\u00e8me, qui comprend dor\u00e9navant un espace d&rsquo;air entre le rev\u00eatement interm\u00e9diaire et l&rsquo;isolant (offert par un isolant rainur\u00e9), ainsi que l&rsquo;ajout d&rsquo;une moulure de d\u00e9part et d&rsquo;un solin larmier. Cet espace d&rsquo;air permet l&rsquo;\u00e9gouttement et l&rsquo;ass\u00e8chement de l&rsquo;humidit\u00e9 qui pourrait s&rsquo;accumuler dans le syst\u00e8me.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-6601\" src=\"https:\/\/cep-experts.ca\/wp-content\/uploads\/2015\/04\/detail-mal-execute.png\" alt=\"\" width=\"1866\" height=\"602\" \/><\/p>\n<p>Des exigences pour les mat\u00e9riaux, l&rsquo;installation et la conception des syst\u00e8mes SIFE, sera int\u00e9gr\u00e9e \u00e0 l&rsquo;\u00e9dition du Code National du b\u00e2timent en incorporant la norme CAN\/ULC.S716<\/p>\n<h4><strong>Conclusion<\/strong><\/h4>\n<p>En conclusion, un changement notable r\u00e9cemment dans la m\u00e9thode d&rsquo;installation d\u00e9montre l&rsquo;ampleur de la probl\u00e9matique. Et bien que les dommages soient graduels, la cause et l&rsquo;origine r\u00e9sultent souvent d&rsquo;un vice de construction ou d&rsquo;une conception inad\u00e9quate pour ce type de rev\u00eatement et un recours peut \u00eatre possible dans plusieurs cas.<\/p>\n<p>Pour en savoir davantage sur le sujet, ou pour nous envoyer une demande d\u2019expertise, veuillez communiquer avec <a href=\"https:\/\/cep-experts.ca\/fr\/experts\/?experts-bureaux=&amp;experts-expertises=1214#filtrer\">l&rsquo;\u00e9quipe de g\u00e9nie civil et structure<\/a> au 877 686-0240 ou <a href=\"mailto:pfortier@cep-experts.ca\">pfortier@cep-experts.ca<\/a><\/p>[\/et_pb_text][\/et_pb_column][\/et_pb_row][\/et_pb_section]","protected":false},"excerpt":{"rendered":"<p>Avec une conscientisation environnementale accrue et l&rsquo;entr\u00e9e en vigueur des nouveaux r\u00e8glements concernant l&rsquo;efficacit\u00e9 \u00e9nerg\u00e9tique des b\u00e2timents, les propri\u00e9taires, gestionnaires, architectes et ing\u00e9nieurs sont \u00e0 la recherche de techniques innovatrices pour r\u00e9pondre \u00e0 ces nouveaux besoins. L&rsquo;augmentation de l&rsquo;isolation thermique de l&rsquo;enveloppe du b\u00e2timent est un moyen efficace de r\u00e9pondre \u00e0 certaines exigences en mati\u00e8re d&rsquo;efficacit\u00e9 \u00e9nerg\u00e9tique.<\/p>\n","protected":false},"author":4,"featured_media":6583,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_et_pb_use_builder":"on","_et_pb_old_content":"","_et_gb_content_width":"","footnotes":""},"class_list":["post-6597","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.2 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>La probl\u00e9matique des syst\u00e8mes d&#039;isolation des fa\u00e7ades avec enduit acrylique - CEP Forensique<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/cep-experts.ca\/fr\/la-problematique-des-systemes-disolation-des-facades-avec-enduit-acrylique\/\" \/>\n<meta property=\"og:locale\" content=\"fr_CA\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"La probl\u00e9matique des syst\u00e8mes d&#039;isolation des fa\u00e7ades avec enduit acrylique - CEP Forensique\" \/>\n<meta property=\"og:description\" content=\"Avec une conscientisation environnementale accrue et l&#039;entr\u00e9e en vigueur des nouveaux r\u00e8glements concernant l&#039;efficacit\u00e9 \u00e9nerg\u00e9tique des b\u00e2timents, les propri\u00e9taires, gestionnaires, architectes et ing\u00e9nieurs sont \u00e0 la recherche de techniques innovatrices pour r\u00e9pondre \u00e0 ces nouveaux besoins. L&#039;augmentation de l&#039;isolation thermique de l&#039;enveloppe du b\u00e2timent est un moyen efficace de r\u00e9pondre \u00e0 certaines exigences en mati\u00e8re d&#039;efficacit\u00e9 \u00e9nerg\u00e9tique.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/cep-experts.ca\/fr\/la-problematique-des-systemes-disolation-des-facades-avec-enduit-acrylique\/\" \/>\n<meta property=\"og:site_name\" content=\"CEP Forensique\" \/>\n<meta property=\"article:published_time\" content=\"2015-04-01T19:59:07+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2022-12-28T21:21:48+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/cep-experts.ca\/wp-content\/uploads\/2020\/02\/structural-damage-2.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"300\" \/>\n\t<meta property=\"og:image:height\" content=\"199\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"cynthia\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u00c9crit par\" \/>\n\t<meta name=\"twitter:data1\" content=\"cynthia\" \/>\n\t<meta name=\"twitter:label2\" content=\"Estimation du temps de lecture\" \/>\n\t<meta name=\"twitter:data2\" content=\"5 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/cep-experts.ca\/fr\/la-problematique-des-systemes-disolation-des-facades-avec-enduit-acrylique\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/cep-experts.ca\/fr\/la-problematique-des-systemes-disolation-des-facades-avec-enduit-acrylique\/\"},\"author\":{\"name\":\"cynthia\",\"@id\":\"https:\/\/cep-experts.ca\/fr\/#\/schema\/person\/bee85dd6361a906d9b914c78747f7480\"},\"headline\":\"La probl\u00e9matique des syst\u00e8mes d&rsquo;isolation des fa\u00e7ades avec enduit acrylique\",\"datePublished\":\"2015-04-01T19:59:07+00:00\",\"dateModified\":\"2022-12-28T21:21:48+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/cep-experts.ca\/fr\/la-problematique-des-systemes-disolation-des-facades-avec-enduit-acrylique\/\"},\"wordCount\":1075,\"image\":{\"@id\":\"https:\/\/cep-experts.ca\/fr\/la-problematique-des-systemes-disolation-des-facades-avec-enduit-acrylique\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/cep-experts.ca\/wp-content\/uploads\/2020\/02\/structural-damage-2.jpg\",\"inLanguage\":\"fr-CA\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/cep-experts.ca\/fr\/la-problematique-des-systemes-disolation-des-facades-avec-enduit-acrylique\/\",\"url\":\"https:\/\/cep-experts.ca\/fr\/la-problematique-des-systemes-disolation-des-facades-avec-enduit-acrylique\/\",\"name\":\"La probl\u00e9matique des syst\u00e8mes d'isolation des fa\u00e7ades avec enduit acrylique - CEP Forensique\",\"isPartOf\":{\"@id\":\"https:\/\/cep-experts.ca\/fr\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/cep-experts.ca\/fr\/la-problematique-des-systemes-disolation-des-facades-avec-enduit-acrylique\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/cep-experts.ca\/fr\/la-problematique-des-systemes-disolation-des-facades-avec-enduit-acrylique\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/cep-experts.ca\/wp-content\/uploads\/2020\/02\/structural-damage-2.jpg\",\"datePublished\":\"2015-04-01T19:59:07+00:00\",\"dateModified\":\"2022-12-28T21:21:48+00:00\",\"author\":{\"@id\":\"https:\/\/cep-experts.ca\/fr\/#\/schema\/person\/bee85dd6361a906d9b914c78747f7480\"},\"breadcrumb\":{\"@id\":\"https:\/\/cep-experts.ca\/fr\/la-problematique-des-systemes-disolation-des-facades-avec-enduit-acrylique\/#breadcrumb\"},\"inLanguage\":\"fr-CA\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/cep-experts.ca\/fr\/la-problematique-des-systemes-disolation-des-facades-avec-enduit-acrylique\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-CA\",\"@id\":\"https:\/\/cep-experts.ca\/fr\/la-problematique-des-systemes-disolation-des-facades-avec-enduit-acrylique\/#primaryimage\",\"url\":\"https:\/\/cep-experts.ca\/wp-content\/uploads\/2020\/02\/structural-damage-2.jpg\",\"contentUrl\":\"https:\/\/cep-experts.ca\/wp-content\/uploads\/2020\/02\/structural-damage-2.jpg\",\"width\":300,\"height\":199},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/cep-experts.ca\/fr\/la-problematique-des-systemes-disolation-des-facades-avec-enduit-acrylique\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Accueil\",\"item\":\"https:\/\/cep-experts.ca\/fr\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"La probl\u00e9matique des syst\u00e8mes d&rsquo;isolation des fa\u00e7ades avec enduit acrylique\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/cep-experts.ca\/fr\/#website\",\"url\":\"https:\/\/cep-experts.ca\/fr\/\",\"name\":\"CEP Forensique\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/cep-experts.ca\/fr\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"fr-CA\"},{\"@type\":\"Person\",\"@id\":\"https:\/\/cep-experts.ca\/fr\/#\/schema\/person\/bee85dd6361a906d9b914c78747f7480\",\"name\":\"cynthia\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"La probl\u00e9matique des syst\u00e8mes d'isolation des fa\u00e7ades avec enduit acrylique - CEP Forensique","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/cep-experts.ca\/fr\/la-problematique-des-systemes-disolation-des-facades-avec-enduit-acrylique\/","og_locale":"fr_CA","og_type":"article","og_title":"La probl\u00e9matique des syst\u00e8mes d'isolation des fa\u00e7ades avec enduit acrylique - CEP Forensique","og_description":"Avec une conscientisation environnementale accrue et l'entr\u00e9e en vigueur des nouveaux r\u00e8glements concernant l'efficacit\u00e9 \u00e9nerg\u00e9tique des b\u00e2timents, les propri\u00e9taires, gestionnaires, architectes et ing\u00e9nieurs sont \u00e0 la recherche de techniques innovatrices pour r\u00e9pondre \u00e0 ces nouveaux besoins. L'augmentation de l'isolation thermique de l'enveloppe du b\u00e2timent est un moyen efficace de r\u00e9pondre \u00e0 certaines exigences en mati\u00e8re d'efficacit\u00e9 \u00e9nerg\u00e9tique.","og_url":"https:\/\/cep-experts.ca\/fr\/la-problematique-des-systemes-disolation-des-facades-avec-enduit-acrylique\/","og_site_name":"CEP Forensique","article_published_time":"2015-04-01T19:59:07+00:00","article_modified_time":"2022-12-28T21:21:48+00:00","og_image":[{"width":300,"height":199,"url":"https:\/\/cep-experts.ca\/wp-content\/uploads\/2020\/02\/structural-damage-2.jpg","type":"image\/jpeg"}],"author":"cynthia","twitter_card":"summary_large_image","twitter_misc":{"\u00c9crit par":"cynthia","Estimation du temps de lecture":"5 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/cep-experts.ca\/fr\/la-problematique-des-systemes-disolation-des-facades-avec-enduit-acrylique\/#article","isPartOf":{"@id":"https:\/\/cep-experts.ca\/fr\/la-problematique-des-systemes-disolation-des-facades-avec-enduit-acrylique\/"},"author":{"name":"cynthia","@id":"https:\/\/cep-experts.ca\/fr\/#\/schema\/person\/bee85dd6361a906d9b914c78747f7480"},"headline":"La probl\u00e9matique des syst\u00e8mes d&rsquo;isolation des fa\u00e7ades avec enduit acrylique","datePublished":"2015-04-01T19:59:07+00:00","dateModified":"2022-12-28T21:21:48+00:00","mainEntityOfPage":{"@id":"https:\/\/cep-experts.ca\/fr\/la-problematique-des-systemes-disolation-des-facades-avec-enduit-acrylique\/"},"wordCount":1075,"image":{"@id":"https:\/\/cep-experts.ca\/fr\/la-problematique-des-systemes-disolation-des-facades-avec-enduit-acrylique\/#primaryimage"},"thumbnailUrl":"https:\/\/cep-experts.ca\/wp-content\/uploads\/2020\/02\/structural-damage-2.jpg","inLanguage":"fr-CA"},{"@type":"WebPage","@id":"https:\/\/cep-experts.ca\/fr\/la-problematique-des-systemes-disolation-des-facades-avec-enduit-acrylique\/","url":"https:\/\/cep-experts.ca\/fr\/la-problematique-des-systemes-disolation-des-facades-avec-enduit-acrylique\/","name":"La probl\u00e9matique des syst\u00e8mes d'isolation des fa\u00e7ades avec enduit acrylique - CEP Forensique","isPartOf":{"@id":"https:\/\/cep-experts.ca\/fr\/#website"},"primaryImageOfPage":{"@id":"https:\/\/cep-experts.ca\/fr\/la-problematique-des-systemes-disolation-des-facades-avec-enduit-acrylique\/#primaryimage"},"image":{"@id":"https:\/\/cep-experts.ca\/fr\/la-problematique-des-systemes-disolation-des-facades-avec-enduit-acrylique\/#primaryimage"},"thumbnailUrl":"https:\/\/cep-experts.ca\/wp-content\/uploads\/2020\/02\/structural-damage-2.jpg","datePublished":"2015-04-01T19:59:07+00:00","dateModified":"2022-12-28T21:21:48+00:00","author":{"@id":"https:\/\/cep-experts.ca\/fr\/#\/schema\/person\/bee85dd6361a906d9b914c78747f7480"},"breadcrumb":{"@id":"https:\/\/cep-experts.ca\/fr\/la-problematique-des-systemes-disolation-des-facades-avec-enduit-acrylique\/#breadcrumb"},"inLanguage":"fr-CA","potentialAction":[{"@type":"ReadAction","target":["https:\/\/cep-experts.ca\/fr\/la-problematique-des-systemes-disolation-des-facades-avec-enduit-acrylique\/"]}]},{"@type":"ImageObject","inLanguage":"fr-CA","@id":"https:\/\/cep-experts.ca\/fr\/la-problematique-des-systemes-disolation-des-facades-avec-enduit-acrylique\/#primaryimage","url":"https:\/\/cep-experts.ca\/wp-content\/uploads\/2020\/02\/structural-damage-2.jpg","contentUrl":"https:\/\/cep-experts.ca\/wp-content\/uploads\/2020\/02\/structural-damage-2.jpg","width":300,"height":199},{"@type":"BreadcrumbList","@id":"https:\/\/cep-experts.ca\/fr\/la-problematique-des-systemes-disolation-des-facades-avec-enduit-acrylique\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Accueil","item":"https:\/\/cep-experts.ca\/fr\/"},{"@type":"ListItem","position":2,"name":"La probl\u00e9matique des syst\u00e8mes d&rsquo;isolation des fa\u00e7ades avec enduit acrylique"}]},{"@type":"WebSite","@id":"https:\/\/cep-experts.ca\/fr\/#website","url":"https:\/\/cep-experts.ca\/fr\/","name":"CEP Forensique","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/cep-experts.ca\/fr\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"fr-CA"},{"@type":"Person","@id":"https:\/\/cep-experts.ca\/fr\/#\/schema\/person\/bee85dd6361a906d9b914c78747f7480","name":"cynthia"}]}},"_links":{"self":[{"href":"https:\/\/cep-experts.ca\/fr\/wp-json\/wp\/v2\/posts\/6597","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/cep-experts.ca\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/cep-experts.ca\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/cep-experts.ca\/fr\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/cep-experts.ca\/fr\/wp-json\/wp\/v2\/comments?post=6597"}],"version-history":[{"count":0,"href":"https:\/\/cep-experts.ca\/fr\/wp-json\/wp\/v2\/posts\/6597\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/cep-experts.ca\/fr\/wp-json\/wp\/v2\/media\/6583"}],"wp:attachment":[{"href":"https:\/\/cep-experts.ca\/fr\/wp-json\/wp\/v2\/media?parent=6597"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}